Product Introduction
ABB IMDSO14 is a digital output module that is part of ABB's Infi 90 distributed control system (DCS). It provides 16 digital output channels. It is a key component in industrial automation systems, enabling precise control of field devices and is suitable for a variety of complex industrial environments.

Technical Specifications
|
Brand |
ABB Bailey |
|
Model |
IMDSO14 |
|
Part Number |
IMDSO14 |
|
Description |
Digital Output Module |
|
Origin |
USA |
|
Dimension |
36*28*8cm |
|
Weight |
0.35kg |
Product Details
The IMDSO14 Digital Output module (DSO) outputs 16 digital signals from the INFI 90 OPEN system to control a process. It is an interface between the process and the INFI 90 OPEN Strategic Process Management System. The signals provide digital switching (ON or OFF) for field devices. Control modules perform the control functions; I/O modules provide the input/ output functions.
Figure 1-1 illustrates the INFI 90 OPEN communication levels and the position of the digital output modules within these levels.
The DSO module consists of a single printed circuit board that occupies one slot in a module mounting unit (MMU). It outputs 16 separate digital signals through solid state circuits on the printed circuit board. Twelve outputs are isolated from each other; the remaining two pairs share common positive output lines.
Two captive screws on the faceplate secure the module to the MMU. The upper two front panel red and greed LEDs indicate the module operating status. The 16 lower front panel red LEDs (group A and group B) display the module output states (ON or OFF).
The DSO module has three card edge connectors for external signals and power (P1, P2 and P3). P1 connects to logic power (+5 VDC) that drives the module circuits. P2 connects the module to the I/O expander bus to communicate with a control module. P3 outputs the digital signals using a cable connected to a termination unit (TU) or a termination module (TM). The terminal blocks (physical connection points) for field wiring are on the TU or TM.

Termination Unit (NTDO02) - Configuration

STATUS INDICATORS
The DSO module has two front panel module status LED indicators to aid in system test and diagnosis. Sixteen front panel indicators display the output states (ON or OFF). The location of the indicators is shown in Figure 4-1.
Module Status Indicators
Table 4-1 describes the states of the module status LED indicators (refer to TROUBLESHOOTING in Section 5 to determine corrective actions).
| Red LED | Green LED | Indication |
| OFF | OFF | No power or not enabled. |
| OFF | ON | Enabled and communicating with control module. |
| ON | OFF | Bus fault timer error (time-out) |
| ON | ON | Not allowed. |
Output Status Indicators
There are 16 front panel indicators (group A and group B) to display the output states. Each indicator represents one digital output. A red LED indicates an energized (ON) output; a blank LED indicates a non-energized (OFF) output.
RELATED PRODUCTS
| SPNIS21 | PBA20000 |
| SPBRC300 BRC300 PHCBRC300 | SPIIT13 |
| BRC410 SPBRC410 | INIIT13 |
| SPBRC400 PHCBRC400 | SPDSO14 |
| IMCPM02 | IMDSO14 |
| INNIS21 | IMDSI14 |
| INNPM12 | SPDSI22 |
| SPNPM22 | SPDSI13 |
| INNPM22 | SPDSI14 |
| IMMFP12 | IMDSI22 |
| INICT12 | SPFEC12 |
| INICT13A | IMDSI14 |