Bently Nevada 133811-02 is a robust, six-channel temperature monitoring device designed for use in severe industrial settings. It provides a sturdy and compact solution for monitoring the temperatures of critical rotating equipment components, including bearings, motors, and gearboxes.

bently nevada 133811-02 3500-61

 

 

 

Technical Specifications  

 

Manufacture

BENTLY NEVADA

Model

3500/61

Part Number

133811-02

Description

Temperature Monitor Modules

Origin

USA

Dimension

26*26*5cm

Weight

0.8kg

 

Product Details

 

The 3500/60 & 61 modules provide six channels of temperature monitoring and accept both Resistance Temperature Detector (RTD) and Thermocouple (TC) temperature inputs. The modules condition these inputs and compare them against user-programmable alarm setpoints.

The 3500/60 and 3500/61 provide identical functionality except that the 3500/61 provides recorder outputs for each of its six channels while the 3500/60 does not.

 

The user programs the modules to perform either RTD or TC temperature measurements using the 3500 Rack Configuration Software. Different I/O modules are available inRTD/TC non-isolated or TC isolated versions. The user can configure the RTD/TC non-isolated version to accept either TC or RTD, or a mixture of TC and RTD inputs. The TC isolated version provides 250 Vdc of channel-to-channel isolation to protect against external interference.

 

When used in a Triple Modular Redundant (TMR) configuration, temperature monitors must be installed adjacent to each other in groups of three. When used in this configuration, the system employs two types of voting to ensure accurate operation and to avoid single-point failures.

 

 

Specifications

 

Inputs
Signal
Accepts from 1 to 6 RTD or TC transducer signals.
Input Impedance
10 MΩ for each lead input.
Power Consumption
 
3500/60
Nominal consumption of 7 watts.
3500/61
Nominal consumption of 9 watts.

 

Tranducers
TCs
 
Type E
-100 °C to +1000 °C, (-148 °F to +1832 °F)
Type J
-18 °C to +760 °C, (+0 °F to +1400 °F)
Type K
-18 °C to +1370 °C, (+0 °F to +2498 °F)
Type T
-160 °C to +400 °C, (-256 °F to +752 °F)
RTDs
 
100Ω 3-wire & 4-wire platinum
RTD (alpha = 0.00385)
-200° C to +850° C (-328 °F to +1562 °F).
With external barriers:
-50 °C to +850 °C (-122 °F to +1562 °F)
100Ω 3-wire & 4-wire platinum
RTD (alpha = 0.00392)
-200 °C to +700 °C (-328 °F to +1292 °F).
With external barriers:
-50 °C to +260 °C (-122 °F to + 1292 °F)
120Ω 3-wire & 4-wire
nickel RTD
-80 °C to +260 °C (-112 °F to +500 °F).
With external barriers:
-50 °C to +260 °C (-122 °F to + 500 °F)
10Ω 3-wire & 4-wire
copper RTD
-100 °C to +260 °C, (-148 °F to +500 °F).
With external barriers:
-50 °C to +260 °C (-122 °F to +500 °F).
I/O Modules
 
 
Isolated I/O Module
System Isolation: 500Vdc
Channel to Channel Isolation: 250 Vdc
Isolation is only required for fault scenarios and these
voltages will not be present on the I/O module inputs when a wiring or field fault occurs.
Outputs
 
OK LED
Indicates when the
Temperature Monitor is operating properly.
TX/RX LED
Indicates then the Temperature
Monitor is communicating with other modules in the 3500 rack.
Bypass LED
Indicates when the Temperature Monitor is in
Bypass Mode.
RTD Current Source Value
925 ±15 µA @ 25° C per transducer (single supply for the 4-wire RTD and two supplies for the 3-wire).
Recorder
+4 to +20 mA. Values are proportional to monitor full-scale. Individual recorder values are provided for each channel. Monitor operation is unaffected by short circuits on recorder outputs.
Voltage Compliance (current output)
0 to +12 Vdc range across load. Load resistance is 0 to 600 Ω.
 
Resolution
0.3662 µA per bit ±0.15% error at room temperature ±0.4% error over temperature range.
Signal Conditioning
 
Full-scale range for each channel is set in the field via 3500 Configuration Software. No calibration is required.
 
RTDs and TCs (except for 10Ω Copper RTDs)
Resolution
1 °C or 1 °F
Accuracy
 
Internal Termination
Non-Isolated
±3 °C at 25 °C (±5.4 °F at 77 °F).
Bulkhead Rack
±3 °C at 25 °C (±5.4 °F at 77 °F).
Standard Rack
±3 °C at 25 °C (±5.4 °F at 77 °F).
External Termination Non-Isolated
 
Bulkhead Rack
±3 °C at 25 °C (±5.4 °F at 77 °F).
Standard Rack
±1 °C at 25 °C (±1.8 °F at 77 °F).
Internal Termination Isolated
 
Bulkhead Rack
±2 °C at 25 °C
(±3.6 °F at 77 °F).
±3 °C at 25 °C
±5.4 °F at 77 °F).
Standard Rack
±3 °C at 25 °C
±5.4 °F at 77 °F).
External Termination Isolated
 
Bulkhead Rack
±1 °C at 25 °C
(±1.8 °F at 77 °F).
Standard Rack
°C at 25 °C
(±1.8 °F at 77 °F)
10 Ω Copper RTDs
 
Resolution
1°C or 1 °F
Accuracy
±3 °C at 25 °C
(±5.4 °F at 77 °F).
Cold Junction Compensation Sensor (used for TCmeasurements)
 
Accuracy
±1° C at 25 °C
(±1.8 °F at 77 °F)

 

 

 

 

Welcome to inquiry!

 

Ms.Smiling Sales Manager┃CHINA

Atten:Smiling

Mobile/WhatsApp/Wechat:+86 18050035902

E-mail: info@htechplc.com

Website: https://www.joyoungintl.com/

Address: Room 1904, No.96-2 Lujiang Road, Siming District, Xiamen,China.

Hot Tags: bently nevada 133811-02 3500/61, China bently nevada 133811-02 3500/61 manufacturers, suppliers, GE IS215TCCBG1BZZ01A DS200TCCBG1BED Communication Module, Prosoft MVI56E MNETR, FOXBORO RH924YA FCP280 Field Control Processor, YOKOGAWA VI702, FOXBORO RH924YA, FOXBORO FCP280